Flexible Rubber Welding Cable for Industrial Yh Yhf H01n2d

Category:

CONSTRUCTION
Conductor
Generally to Class 6 flexible copper conductor according to IEC 60228 BS EN 60228 (previously BS 6360)
Separator
PET (Polyester Tape)
Sheath
The rubber compound,
Technical data
Voltage Rating
100V
Working temperature:65ºC

Temperature Rating
Fixed: -40°C to +85°C
Flexed: -20°C to +85°C
Minimum Bending Radius
Flexed: 6 x overall diameter

Model Name Main applications Working temperature
of core ≤0C
YH Natural Rubber Sheath for Welding Cable Always used indoor 65
YHF Neoprene Rubber Sheath Welding Cable Always used outdoor 65
Synthetic elastomer Sheath Welding Cable
Conductor Nominal Section (mm2) Conductive Core Thickness of Section Sheath (mm) Average Outer Diameter (mm2) 20oC Conductor Resistance≤(Ω/km) Reference Weight(kg/km)
Number/Diameter of Core(mm) Min Max YH YHF
10 322/0.20 1.8 7.5 9.7 1.91 146 153
16 513/0.20 2.0 9.2 11.5 1.16 218 230
25 798/0.20 2.0 10.5 13.0 0.758 316 331
35 1121/0.20 2.0 11.5 14.5 0.536 426 439
50 1596/0.20 2.2 13.5 17.0 0.379 592 610
70 2214/0.20 2.4 15.0 19.5 0.268 790 817
95 2997/0.20 2.6 17.0 22.0 0.198 1066 1102
120 1702/0.30 2.8 19.0 24.0 0.161 1348 1392
150 2135/0.30 3.0 21.0 27.0 0.129 1678 1698
185 1443/0.40 3.2 22.0 29.0 0.106 1983 2020