Application
For connecting electric appliances, devices and instruments to the power supply network.
Technical Data
- Manufactured acc. to HD 21.12
- Rated voltage Uo/U: 300/300 V
- Test voltage: 2 kV
- Insulation resistance at 70 °C, min 2 x 10^10 Ω.cm
- Maximum conductor temperature: +90 °C
- Max. conductor temperature at short circuit for 5 s: +160 °C
- Temperature of environment: mobile: -5 °C to +80 °C; fixed: -20 °C to +50 °C
- Minimum temperature during installation: -5 °C
- Minimum bending radius: mobile: 15D; fixed: 4D (D- diameter or height of cable)
- Flame test: flame-retardant acc. to IEC 60332-1
- Sheath colour: white, black or other upon request
Cable Design
- Copper conductors class 5 acc. to IEC 60228
- Insulation: PVC compound type TI3 according to HD 21.1
- Sheath: PVC compound type TM3 according to HD 21.1
- H03V2V2-F: twisted cores – circular
- H03V2V2H2-F: cores laid parallel – flat
Core Identification (in accordance to HD 308 S2)
| No of cores | Cables without protective conductor | Cables with protective conductor |
|---|---|---|
| 2 | brown, blue | -3 brown, black, grey green-yellow, blue, brown |
| 3 | – | green-yellow, brown, black, grey |
| 4 | blue, brown, black, grey | green-yellow, brown, black, grey |
Cable Specifications
| No of conductors and cross section | No x mm² | Cable size mm | Copper weight kg/km | Cable weight kg/km |
|---|---|---|---|---|
| H03V2V2-F | 2 x 0,5 | 5,0 | 9,6 | 36 |
| 3 x 0,5 | 5,3 | 14,4 | 43 | |
| 4 x 0,5 | 5,8 | 19,2 | 54 | |
| 2 x 0,75 | 5,5 | 14,4 | 45 | |
| 3 x 0,75 | 5,8 | 21,6 | 55 | |
| 4 x 0,75 | 6,4 | 28,8 | 69 | |
| H03V2V2H2-F | 2 x 0,5 | 3,2 x 5,1 | 9,6 | 27 |
| 2 x 0,75 | 3,4 x 5,6 | 14,4 | 35 |