Low Smoke Halogen Free Cable

Low Smoke Zero Halogen (LSZH) cables are specially engineered for applications where smoke emissions and toxic fumes could pose significant risks to human life and sensitive equipment during fire events. These cables are designed with materials that significantly reduce the amount of smoke produced and eliminate halogen content, resulting in safer evacuation conditions and reduced equipment damage.

Applications and Use Cases

LSZH cables are recommended for installations where human safety and equipment protection are priorities:

  • Public transportation systems (subways, airports, train stations)
  • High-occupancy buildings (hospitals, schools, shopping centers)
  • Critical infrastructure facilities (data centers, power plants, emergency services)
  • Confined spaces with limited evacuation routes
  • Areas housing sensitive electronic equipment
  • Buildings with stringent fire safety regulations

Installation Conditions

The following specifications assume standard installation conditions:

  • Ambient Air Temperature: 30°C
  • Ground Temperature: 20°C
  • Depth of Laying: 0.50 meters
  • Soil Thermal Resistivity: 1.0°C m/W

CU/MICA/XLPE/SWA/LSHF 3 Core Cables

Product Code Conductor Size (mm²) Overall Diameter (mm) Cable Weight (kg/km) Max. DC Resistance at 20°C (Ω/km) Max. AC Resistance at 90°C (Ω/km) Current Rating (A) Ground Current Rating (A) Duct Current Rating (A) Free Air
03C095CTMXC0LWL 95 38.8 4323 0.193 0.246 342 253 322
03C120CTMXC0LWL 120 42.1 5164 0.153 0.195 390 290 375
03C150CTMXC0LWL 150 47.6 6620 0.124 0.158 434 330 426
03C185CTMXC0LWL 185 51.6 7939 0.0991 0.126 490 375 490
03C240CTMXC0LWL 240 56.1 9868 0.0754 0.096 565 436 579
03C300CTMXC0LWL 300 61.0 11925 0.0601 0.076 634 496 663
03C400CTMXC0LWL 400 68.2 14918 0.047 0.059 715 567 769

AL/XLPE/SWA/LSHF 3 Core Cables

Product Code Conductor Size (mm²) Conductor Shape Overall Diameter (mm) Cable Weight (kg/km) Max. DC Resistance at 20°C (Ω/km) Max. AC Resistance at 90°C (Ω/km) Current Rating (A) Ground Current Rating (A) Duct Current Rating (A) Free Air
N03C01.5CT0XC000L 1.5 RM 10.4 151 12.1 15.43 33 25 25
N03C02.5CT0XC000L 2.5 RM 11.2 190 7.41 9.45 43 33 33
N03C004CT0XC000L 4 RM 12.5 256 4.61 5.88 56 44 44
N03C006CT0XC000L 6 RM 13.6 326 3.08 3.93 70 54 56
N03C010CT0XC000L 10 RM 15.3 419 1.83 2.33 94 73 78
N03C016CT0XC000L 16 RM 17.3 600 1.15 1.47 122 90 100
N03C025CT0XC000L 25 SM 18.0 864.0 0.7 0.9 150.0 122.0 128.0

Note: RM = Round, Stranded; SM = Sector, Stranded; SM/RM = Sector for Phase, Round for Neutral