Descriere Detaliată
What a Computer and Instrumentation Cable Does in a Signal Circuit
A computer and instrumentation cable carries low-level signals — analogue measurement loops, control signals, and data links — between a field device and the panel or controller that reads it. The conductors are small and the signal is weak, so the cable's job is less about carrying current and more about keeping the signal intact along the route.
That is why the construction in this range is built around screening rather than around insulation thickness. The signal level is low enough that interference coupled onto the conductors becomes a measurement error, and the interference sources on an industrial site — variable frequency drives, contactor coils, welding equipment, adjacent power cables — are close by.
The DJYPVP and DJYPVRP types are the Chinese GB designations for this class of shielded computer and instrumentation cable, and the range is built in a solid-conductor form and in a multi-strand oxygen-free copper form.
Construction: Conductor, PE Insulation, and Two Shield Layers
The cable is built from five layers, and the screening is the part that takes the space:
- Conductor — oxygen-free copper, in single-solid or multi-strand form. The solid form holds a stable geometry for a fixed installation; the stranded form is used where the route needs flexibility.
- Insulation — polyethylene (PE), applied over each conductor. PE gives a stable dielectric along the length, which is the property that keeps a signal loop consistent from one end to the other.
- Individual screen — an oxygen-free copper braid applied around each pair or group. This is the layer that controls coupling between adjacent circuits inside the same cable.
- Overall screen — aluminium foil with a 360° circumferential wrap, backed by a water-blocking film, and then an overall copper braid. The foil closes the electrostatic path around the whole assembly; the braid carries the screen current and handles the magnetic component.
- Sheath — a flame retardant PVC compound, applied at a thickened wall for abrasion and ageing resistance.
Why the Screen Is Built in Two Layers
A single overall screen handles interference entering the cable from outside, but it does nothing about coupling between the circuits inside. In an instrumentation bundle where several loops share one jacket, that internal coupling is a real error source: a signal on one pair induces a voltage on its neighbour.
The two-layer arrangement separates the two problems. The individual braid around each pair addresses internal crosstalk, and the overall foil-plus-braid addresses the external field. The 360° foil wrap matters here because a foil that is wrapped with a longitudinal overlap gap leaves a slot through which electrostatic coupling passes — a full circumferential wrap does not.
The water-blocking film behind the foil has a second function beyond moisture: it keeps the foil in contact with the braid along the length, so the two screen layers act as one electrical screen rather than as two separate layers with an intermittent connection.
Where the Cable Is Installed
The range is used in four settings where signal integrity and cable density meet:
- Data centres and server rooms — signal and control circuits between cabinets, in trays where power and data run close together.
- Modern warehouses and logistics floors — conveyor control, sortation signalling, and scanner data links.
- Wastewater treatment plants — sensor and control loops between field instruments and the plant control room.
- Digital broadcast and public address systems — signal distribution in commercial and institutional buildings.
Certification, Lengths, and Ordering
The cable carries CCC, ISO 9001, and RoHS. CCC is the relevant mark for the Chinese domestic market; for an export project, confirm which certification the destination requires before the order is placed, since the marking follows the market rather than the construction.
Supply is a 100 m or 200 m coil with a certificate, and lengths below 100 m as measured cut lengths. The sheath is machine-printed with metre marking and the product designation, so the installed length and the cable type can both be read from the jacket at commissioning.
To specify the cable, three items decide the model: the number of pairs or cores, the conductor cross-section, and whether a solid or stranded conductor is required. Add the route — tray, duct, or cabinet — and the screening requirement for the environment, and the model is matched to the circuit. Send those details through the enquiry form on this page.