Silicone Battery Connection Cable — Flexible Tinned Copper Battery Lead with Tin-Plated Copper Lugs, Brass Terminal Clamps, PP Conduit, 4 to 2 AWG, −60 °C to +200 °C, 600 V
EV-laddning och Förnybara Energikablar /Silicone Battery Cable

Silicone Battery Connection Cable — Flexible Tinned Copper Battery Lead with Tin-Plated Copper Lugs, Brass Terminal Clamps, PP Conduit, 4 to 2 AWG, −60 °C to +200 °C, 600 V

Silicone battery connection cable: tinned copper lead with tin-plated copper lugs and brass terminal clamps, PP conduit, 4 to 2 AWG, rated −60 °C to +200 °C at 600 V.

Viktigaste Funktionerna

−60 °C to +200 °C silicone insulation — a range that covers a battery bay in a cold store and the radiant heat beside an engine or a battery cabinet, where a PVC lead would harden and crack
Tinned copper conductor — the tin coating stops the copper from oxidizing at the lug, which is the joint that fails first on a battery lead exposed to acid mist and damp
Tin-plated copper lugs, A-grade copper, thickened — the lug is the current bottleneck on a battery lead, and a thickened copper lug with a tin surface carries the start current without heating at the crimp
Brass terminal clamps, tin plated — negative clamp 15–17 mm internal diameter and positive clamp 17–19 mm, the two sizes that fit most automotive and industrial battery posts
PP flame retardant conduit over the lead — the polypropylene corrugated sleeve protects the silicone from abrasion and chafing against a battery tray edge, while staying flexible
600 V rating — the class required for a battery connection that may be part of a series string in a storage system, not only a 12 V or 24 V vehicle battery
4 AWG, 3 AWG, and 2 AWG builds — 25, 33.7, and 50 mm², matched to SC35, SC50, and SC70 lugs respectively
Length and terminal customizable — the lead is built to the required length with the lug bore and clamp size selected for the battery

Tillämpningar

Automotive and commercial vehicle batteries — the positive and negative leads between the battery post and the chassis or the starter circuitLithium battery storage systems — string and bank interconnection leads inside a storage cabinet or rackBattery energy storage cabinets — the connection between the battery module terminals and the busbarElectrical panel and distribution box wiring — heavy current links where a flexible lead is easier to dress than a rigid barEquipment earthing and bonding — cross-connection leads between enclosures and earth barsIndustrial machinery and medical equipment — high current DC links in equipment where a flexible connection is required

Tekniska Specifikationer

Product Type Battery connection lead, assembled with lugs and terminal clamps
Conductor Material Oxygen-free tinned copper
Conductor Construction (Examples) 6700/0.08 TS, 5000/0.08 TS (tinned strands)
Insulation Silicone rubber, extra flexible
Outer Protection PP (polypropylene) flame retardant corrugated conduit
Rated Voltage 600 V
Test Voltage 600 V
Temperature Range −60 °C to +200 °C
Sizes 4 AWG (25 mm²), 3 AWG (33.7 mm²), 2 AWG (50 mm²)
Lug Type SC series copper lug, A-grade copper, thickened, tin plated
Lug Matching 4 AWG / 25 mm² — SC35-8; 3 AWG / 33.7 mm² — SC50-8; 2 AWG / 50 mm² — SC70-8
Lug Bore M8 standard; M10 and M12 available for volume orders
Terminal Clamp Brass, tin plated
Negative Clamp Inner Diameter 15–17 mm
Positive Clamp Inner Diameter 17–19 mm
Clamp Screw Steel
Colours Red (positive) and black (negative)
Diameter Tolerance 0.1 mm
Standards EN 50525-1:2011; EN 50525-2-41:2011; EN 50525-2-83:2011; CE per 2014/35/EU (Low Voltage Directive)
Certifications CE; test report available
Customization Length and terminal configuration built to requirement; other colours and clamp sizes on request
Packing 100 m per coil for bulk cable; assembled leads packed to order
Application Vehicle batteries, lithium battery storage, battery energy storage cabinets, panel wiring, earthing and bonding, industrial and medical equipment

Detaljerad Beskrivning

What a Battery Connection Lead Has to Survive

A battery lead lives in a hostile place for a cable. It sits next to a lead-acid battery that vents acid mist, it is bent into a tight radius to reach the post, it carries the starter current for a few seconds at a time, and it is often exposed to engine heat or to the inside of a storage cabinet.

Four failure modes follow from that, and the construction addresses each one:

  • Oxidation at the lug — acid mist and damp attack the copper at the crimp, raising the joint resistance until it heats. A tinned conductor and a tin-plated lug both resist that.
  • Stiffening of the insulation — a PVC lead hardens at low temperature and cracks where it is bent. A silicone lead stays flexible across −60 °C to +200 °C.
  • Abrasion against the tray — the lead rubs where it passes an edge. The PP conduit takes the wear instead of the silicone.
  • Heating at the terminal — the lug is the narrowest part of the current path. A thickened copper lug carries the start current without a hot spot at the crimp.

Construction: Silicone, Tinned Copper, and the Lug Stack

The lead is built as an assembly rather than as bulk cable, and the layers run from the conductor out to the terminal hardware:

  • Conductor — oxygen-free tinned copper in a fine stranding. The stranding is what allows the lead to be bent into a tight radius at the post without work-hardening the copper.
  • Insulation — extra flexible silicone rubber, rated −60 °C to +200 °C. The silicone is what keeps the lead workable in a cold battery bay and stable next to engine heat.
  • Conduit — PP flame retardant corrugated sleeve over the silicone. It is the abrasion barrier, and it also adds a layer of flame resistance along the run.
  • Lug — SC series copper lug in thickened A-grade copper with a tin plating. The tin is there for the acid mist, not for conductivity.
  • Clamp — brass terminal clamp, tin plated, with a steel screw. The brass body carries the current and the steel screw holds the clamp closed without stripping.

Ratings and Sizes

ParameterValue
Rated voltage600 V
Test voltage600 V
Temperature range−60 °C to +200 °C
Sizes4 AWG (25 mm²), 3 AWG (33.7 mm²), 2 AWG (50 mm²)
ConductorOxygen-free tinned copper
InsulationSilicone rubber
Outer protectionPP flame retardant conduit
LugSC copper, A-grade, thickened, tin plated
Lug matchingSC35-8 / SC50-8 / SC70-8
Lug boreM8 standard; M10, M12 on volume orders
Negative clamp15–17 mm internal diameter
Positive clamp17–19 mm internal diameter
ColoursRed and black
StandardsEN 50525-1, EN 50525-2-41, EN 50525-2-83; CE per 2014/35/EU

The 600 V rating is worth noting for a lead that most people associate with a 12 V battery. It is the class required where the lead becomes part of a series string in a storage system, and it is what separates this assembly from a low-voltage automotive jumper lead.

Terminal Options and Custom Lengths

The lead is assembled to order, so three items are specified rather than selected from a stock list:

  • Length, measured from lug face to lug face rather than along the cable
  • Lug bore, M8 as standard, with M10 and M12 available for volume orders
  • Clamp size, 15–17 mm for the negative post and 17–19 mm for the positive post
Red and black are the standard colours, matching the positive and negative convention. Other colours are available on request.

Certification and Ordering

The cable is built to EN 50525-1, EN 50525-2-41, and EN 50525-2-83, and carries CE under the Low Voltage Directive 2014/35/EU. A test report is available. For a project outside the EU, confirm which certification the destination market requires, because the marking follows the market rather than the construction.

Assembled leads are packed to order, and bulk cable is supplied on a 100 m coil with lengths below 100 m as measured cut lengths.

To specify the lead, send the length, the battery post size, the lug bore, and the nominal current the lead will carry. Those four items fix the conductor size, the lug, and the clamp, and the assembly is quoted against them through the enquiry form on this page.

Vanliga Frågor

Why silicone insulation instead of PVC for a battery lead?

Temperature and flexibility. A battery bay reaches temperatures that harden PVC, and a PVC lead becomes stiff and cracks at the lug where it is bent during installation. Silicone holds −60 °C to +200 °C and stays flexible across that range, which is why it is used where the lead has to be dressed into a tight space around a battery box.

What clamp sizes fit which battery post?

The negative clamp has a 15–17 mm internal diameter and the positive clamp 17–19 mm. Those are the two common automotive and light industrial post sizes. The clamps are brass with a tin plating, and the screws are steel — copper screws were found to break too easily during tightening and were replaced.

Which lug sizes go with which cable size?

The three standard builds are 4 AWG (25 mm²) with an SC35-8 lug, 3 AWG (33.7 mm²) with an SC50-8 lug, and 2 AWG (50 mm²) with an SC70-8 lug. The lug bore is M8 by default, with M10 and M12 available for volume orders.

Can the lead be made to a specific length?

Yes. The lead is assembled to order, so the length, the lug bore, the clamp size, and the colour are specified for the installation. Send the required length measured from lug face to lug face, together with the battery post size.

What is the corrugated sleeve for?

It is a PP flame retardant conduit over the silicone lead. Its job is abrasion protection — a battery lead rubs against a tray edge or a metal guard, and silicone alone is soft enough to wear through. The conduit takes the abrasion while the silicone underneath stays intact.

Fråga om Produkt

Produkt: Silicone Battery Connection Cable — Flexible Tinned Copper Battery Lead with Tin-Plated Copper Lugs, Brass Terminal Clamps, PP Conduit, 4 to 2 AWG, −60 °C to +200 °C, 600 V

Lägg till tekniska specifikationer (valfritt)

Ju fler detaljer du anger, desto snabbare och mer exakt blir vår offert.

Ingen fil vald

PDF, Office, bild eller CAD-fil — upp till 5 MB

Behöver du Hjälp?

Certifieringar

ISO 9001
Kvalitet
CE
Europeisk
RoHS
Miljö
TÜV
Certifiering

Behöver du en Offert för denna Produkt?

Skicka oss dina krav och få en detaljerad offert inom 24 timmar.