WDZN-RYYP LSZH Shielded Cable — Low Smoke Zero Halogen Signal Cable with Tinned Copper Braid and Aluminium Foil Screen, Halogen-Free Sheath, for Rail Rolling Stock and Long Signal Runs
Brandbeständiga, Högtemperatur- och LSZH-kablar /LSZH Shielded Control Cable

WDZN-RYYP LSZH Shielded Cable — Low Smoke Zero Halogen Signal Cable with Tinned Copper Braid and Aluminium Foil Screen, Halogen-Free Sheath, for Rail Rolling Stock and Long Signal Runs

WDZN-RYYP low smoke zero halogen shielded cable: tinned copper braid plus aluminium foil screen, halogen-free insulation and sheath, 3 or 4 cores at 0.5 mm², for rail.

Viktigaste Funktionerna

Halogen-free insulation and sheath — both the core insulation and the outer sheath use a halogen-free compound, so combustion produces low smoke and no corrosive halogen gas rather than the dense acidic smoke of a PVC cable
Self-extinguishing after the flame is removed — the compound stops burning once the ignition source is taken away, which is what limits flame spread along a cable run inside a vehicle or a tunnel
Two screen layers — aluminium foil backing plus a tinned copper braid, so the cable holds a signal on a long run through an environment with heavy magnetic fields
Tinned copper braid instead of bare copper — the tin coating resists oxidation on the braid, which keeps the screen-to-ground path stable over the service life
Ultra-fine oxygen-free copper conductor — a fine strand construction that keeps the core flexible while holding resistance low along the run
3-core and 4-core constructions at 0.5 mm² — the sizes used for signal and control circuits in rolling stock wiring
Thin-wall extrusion with low eccentricity — an even insulation wall around the conductor avoids the thin spots that lead to insulation breakdown
Metre marking and full-length delivery — the sheath is printed with metre marking, and the coil is supplied to the stated length

Tillämpningar

High-speed rail and EMU internal wiring — signal and control circuits inside the car body, where halogen-free materials are specified for passenger safetyLocomotive and passenger train wiring — inter-car and underfloor signal runs on rolling stockRail track-side and tunnel installations — signal cable runs where smoke emission in a fire is a life-safety issue rather than a property-damage issueLong-distance signal transmission — analogue and control signals over runs where screen integrity has to holdHigh magnetic field environments — routes close to traction converters, transformers, and traction motors, where an unscreened cable would pick up induced noiseGeneral low smoke zero halogen installations — cabinets and public buildings where a halogen-free cable is required by specification

Tekniska Specifikationer

Product Type Low smoke zero halogen shielded signal and control cable
Type Designation WDZN-RYYP
Conductor Material Ultra-fine oxygen-free copper
Core Count 3-core and 4-core
Conductor Cross-Section 0.5 mm²
Insulation Halogen-free insulation compound
Screen Layer 1 Aluminium foil backing
Screen Layer 2 Tinned copper braid
Sheath Material Halogen-free, low smoke compound
Sheath Colour Black
Flame Behaviour Self-extinguishing after removal of the ignition source; low smoke emission; no halogen gas
Smoke and Gas Emission Low smoke, no corrosive halogen gas, no irritating odour on combustion
Eccentricity Thin-wall extrusion with low eccentricity for an even insulation wall
Customization Conductor construction can be customized to customer requirement
Marking Metre marking and product designation printed on the sheath
Certifications CCC
Packing 100 m or 200 m per coil with certificate; lengths below 100 m supplied as measured cut lengths
Application High-speed rail, EMU, locomotive and train wiring, rail track-side signal runs, long-distance signal transmission in high magnetic field environments

Detaljerad Beskrivning

Why Low Smoke Zero Halogen Matters Inside a Train

A cable fire inside a train or a tunnel is not primarily a property-damage event. The hazard is the smoke and the gas, because the people inside have nowhere to go while the atmosphere fills. That is the reason rolling stock wiring specifies low smoke zero halogen constructions rather than ordinary PVC cable.

The difference is measurable in the two failure modes that matter. Smoke density determines whether an escape route stays visible. Halogen content determines whether the combustion gases are acidic and corrosive — hydrogen chloride from PVC attacks lungs, corrodes electronic equipment, and damages structural steel, and it does so at concentrations far below what a visible flame would suggest.

The WDZN-RYYP construction addresses both. The insulation and the sheath are halogen-free, the cable is self-extinguishing once the ignition source is removed, and smoke emission stays low.

Construction: Five Layers from Conductor to Sheath

The cable is built in five layers, and each one has a separate function:

  • Conductor — ultra-fine oxygen-free copper. The fine stranding keeps the core flexible for wiring inside a car body while holding the resistance low over a long run.
  • Insulation — a halogen-free compound applied as a thin wall. The extrusion is controlled for low eccentricity, so the wall is even around the conductor rather than thin on one side, which is where insulation breakdown starts.
  • Screen layer 1 — aluminium foil backing. It provides a continuous 360° barrier against electrostatic coupling along the length of the cable.
  • Screen layer 2 — tinned copper braid. The braid carries the screen current and deals with the magnetic component of the interference; the tin coating keeps the braid from oxidizing, so the ground path stays stable.
  • Sheath — a halogen-free, low smoke compound in black, applied over the screened assembly.

What the Two Screen Layers Do on a Long Signal Run

On a short jumper, a single screen is usually enough. On a long run through a vehicle or a tunnel, the two interference mechanisms have to be handled separately.

Electrostatic coupling is blocked by a continuous conductor around the cores, which is what the foil provides — a full wrap with no longitudinal gap. Magnetic coupling is not blocked by a thin foil, because the foil has too little cross-section to carry the induced current. That is the braid's job, and it is why the two layers are used together rather than choosing one.

The tinned finish on the braid is part of the same argument. The screen only works if it stays connected to ground along the entire run, and a braid that oxidizes develops a rising resistance at exactly the points where the connection matters.

Where WDZN-RYYP Cable Is Used

The construction is specified in four situations:

  • High-speed rail and EMU car wiring — signal and control circuits inside the passenger envelope, where halogen-free materials are a safety requirement.
  • Locomotive and passenger train wiring — inter-car and underfloor signal runs.
  • Track-side and tunnel installations — signal runs where smoke in a fire is a life-safety issue.
  • Long signal runs in high magnetic field environments — routes near traction converters, transformers, and traction motors, where an unscreened cable would pick up induced noise.
It is also used where a project specification simply calls for a halogen-free shielded cable in a cabinet or a public building.

Certification and Ordering

The cable carries CCC, which is the relevant mark for the Chinese domestic market and for rolling stock built to Chinese standards. For an export project, confirm which certification the destination market requires before ordering, because the marking follows the market rather than the construction.

Supply is a 100 m or 200 m coil with a certificate, and lengths below 100 m as measured cut lengths. The sheath is printed with metre marking, so the installed length can be read directly from the cable at commissioning.

To specify the cable, state the core count (3 or 4), the cross-section, the route length, and whether the environment is a passenger compartment, an underfloor run, or a track-side duct. Send those through the enquiry form on this page and the construction is confirmed against them.

Vanliga Frågor

What does low smoke zero halogen actually change compared with a PVC cable?

Two things, and they matter in different ways. Low smoke means the cable emits far less visible smoke while burning, which keeps escape routes visible. Zero halogen means the combustion gases are not acidic or corrosive, so they do not attack lungs, electronic equipment, or structural steel. A PVC cable produces dense, acidic smoke, which is why halogen-free cable is specified for enclosed passenger spaces and tunnels.

Why is the braid tinned copper rather than bare copper?

The braid is the screen, and its job depends on a stable connection to ground along the whole run. Bare copper braid oxidizes, and the oxide layer raises the resistance of that connection over time. Tinning protects the strands, so the screen impedance stays where it was designed.

What are the two screen layers doing that one layer would not?

The aluminium foil is a continuous 360° layer that blocks electrostatic coupling, and the tinned copper braid carries the screen current and handles the magnetic component of the interference. Used together, the foil closes the gaps that a braid weave leaves, and the braid provides the low-resistance path that a thin foil alone does not.

Which core counts and sizes are available?

The standard constructions are 3-core and 4-core at 0.5 mm², which are the sizes used for signal and control circuits in rolling stock wiring. The conductor construction can also be customized when a project needs a different arrangement.

How is the cable supplied?

Standard coils are 100 m and 200 m with a certificate, and lengths below 100 m are supplied as measured cut lengths. The sheath carries metre marking, so the installed length can be read off the cable.

Fråga om Produkt

Produkt: WDZN-RYYP LSZH Shielded Cable — Low Smoke Zero Halogen Signal Cable with Tinned Copper Braid and Aluminium Foil Screen, Halogen-Free Sheath, for Rail Rolling Stock and Long Signal Runs

Lägg till tekniska specifikationer (valfritt)

Ju fler detaljer du anger, desto snabbare och mer exakt blir vår offert.

Ingen fil vald

PDF, Office, bild eller CAD-fil — upp till 5 MB

Behöver du Hjälp?

Certifieringar

ISO 9001
Kvalitet
CE
Europeisk
RoHS
Miljö
TÜV
Certifiering

Behöver du en Offert för denna Produkt?