AGRP High Temperature Cable 300°C — Fibreglass Braided Silicone Cable with Tinned Copper Conductor, Rated 300/500 V and −60 °C to +300 °C, for Metallurgy, Instrumentation, and Lighting
Yangına Dayanıklı, Yüksek Sıcaklık ve LSZH Kabloları /High Temperature Braided Cable

AGRP High Temperature Cable 300°C — Fibreglass Braided Silicone Cable with Tinned Copper Conductor, Rated 300/500 V and −60 °C to +300 °C, for Metallurgy, Instrumentation, and Lighting

AGRP high temperature cable rated −60 °C to +300 °C and 300/500 V: tinned copper conductor, silicone insulation, fibreglass braid, 0.5 to 6 mm², self-extinguishing.

Ana Özellikler

Continuous rating to +300 °C and down to −60 °C — the range covers both the radiant heat beside a furnace or a ladle and the cold of an unheated outdoor installation, without changing the cable
Fibreglass braid over silicone insulation — the braid is the outer barrier against abrasion and radiant heat, and the silicone underneath provides the dielectric strength, so each layer does the job the other cannot
Core survives two minutes of direct flame — the braided and silicone layers protect the conductor long enough for a circuit to be shut down, rather than failing at the first contact with flame
Self-extinguishing once the flame is removed — the cable stops burning when the ignition source is taken away, so it does not propagate a fire along a tray
Tinned copper conductor — the tin coating resists oxidation at the temperatures where bare copper would darken and increase in resistance
Oil, water, and heat resistant — the braided outer layer sheds oil and water rather than absorbing them, which matters on a shop floor where coolant and lubricant are present
Flexible and tensile-resistant — the silicone core and the braided sheath together allow the cable to be routed around equipment without a minimum-bend penalty typical of a rigid high-temperature cable
0.5, 1, 2.5, 4, and 6 mm² — the cross-sections used for instrumentation, power, and lighting circuits in high-temperature areas

Uygulamalar

Metallurgy and foundry equipment — wiring near furnaces, ladles, and heat-treatment lines where the ambient temperature is above what a PVC or standard silicone cable can takeIndustrial instrumentation in hot zones — sensor and signal leads on equipment that runs hotPower and lighting circuits in high-temperature areas — fixture wiring and distribution in plants where the route passes close to a heat sourceElectrical and electronic equipment — internal and inter-unit wiring in appliances and equipment that generate heat in serviceTelecommunications equipment — wiring in cabinets and enclosures where heat build-up is a design constraintConstruction and building services — high-temperature routes in building engineering where a standard cable would degrade

Teknik Özellikler

Product Type High temperature fibreglass braided silicone cable
Type Designation AGRP
Conductor Material Tinned copper
Conductor Construction Stranded, high-purity tinned copper
Insulation Environmentally friendly silicone rubber
Outer Braid High temperature fibreglass braid, heat treated
Rated Voltage 300/500 V
Temperature Range −60 °C to +300 °C
Cross-Sections 0.5, 1, 2.5, 4, 6 mm²
Flame Behaviour Self-extinguishing after removal of the ignition source
Flame Performance Core intact after two minutes of direct flame exposure
Chemical Resistance Oil resistant, water resistant, heat resistant, corrosion resistant
Mechanical Properties Flexible, tensile resistant, abrasion resistant
Immersion Test Cable intact after 60 days of immersion
Eccentricity Low eccentricity, even wall thickness to prevent insulation breakdown
Length 95 m per coil, length customizable
Packing Standard coil 95 m; lengths below 100 m supplied as measured cut lengths for other models in the range
Application Metallurgy, instrumentation, power and lighting, electrical and electronic equipment, telecommunications, construction

Detaylı Açıklama

What a 300 °C Rating Means in Practice

A 300 °C cable is not simply a silicone cable with a higher number on the datasheet. At that temperature, the failure modes change: the conductor oxidizes faster, the insulation softens and loses mechanical strength, and anything pressed against the cable — a tray edge, a clamp, a metal guard — will cut through a soft insulation wall.

That is why the AGRP construction has two layers doing two different jobs. The silicone provides the dielectric strength and stays flexible across the range, and the fibreglass braid on the outside takes the abrasion and the radiant heat. The rating is the result of the pair, not of either layer alone.

The cable is rated 300/500 V and covers −60 °C to +300 °C, from the radiant heat beside a furnace or a ladle to the cold of an unheated outdoor route.

Construction: Tinned Copper, Silicone, and the Fibreglass Braid

The build runs from the conductor outward in three layers:

  • Conductor — high-purity tinned copper, stranded. The tin coating is there for the temperature: at 300 °C, bare copper oxidizes and the oxide layer raises the resistance of the joint and of the conductor surface. Tinning holds the surface stable.
  • Insulation — environmentally friendly silicone rubber, extruded at a controlled wall with low eccentricity. An even wall is what prevents the thin spot that becomes the breakdown point.
  • Outer braid — high temperature fibreglass, heat treated and braided over the insulation. It is the abrasion barrier, the radiant-heat barrier, and the layer that sheds oil and water rather than absorbing them.
Two properties come from the braid rather than from the silicone: resistance to abrasion, and resistance to oil and water on a shop floor. Two come from the silicone: dielectric strength, and flexibility at temperature.

Electrical and Thermal Ratings

ParameterValue
Rated voltage300/500 V
Temperature range−60 °C to +300 °C
Cross-sections0.5, 1, 2.5, 4, 6 mm²
ConductorTinned copper, stranded
InsulationSilicone rubber
Outer braidHeat-treated fibreglass
Flame behaviourSelf-extinguishing after flame removal
Flame performanceCore intact after 2 minutes of direct flame
Chemical resistanceOil, water, heat, corrosion
Immersion testIntact after 60 days
Standard length95 m per coil, customizable

The flame figures deserve a note. Self-extinguishing and a two-minute intact core are useful properties for a plant cable, but they are not the same as circuit integrity under fire conditions. Where a circuit must keep working during a fire — an alarm, a pressurisation fan, an evacuation system — a fire resistant cable tested to a fire test standard is the correct product, not a high-temperature cable.

Where the Cable Is Used

The construction is specified in six settings, all of them defined by heat rather than by current:

  • Metallurgy and foundry — wiring near furnaces, ladles, and heat-treatment lines, where the ambient temperature is above what PVC or a standard silicone cable can take.
  • Instrumentation in hot zones — sensor and signal leads on equipment that runs hot.
  • Power and lighting in high-temperature areas — fixture wiring and distribution where the route passes close to a heat source.
  • Electrical and electronic equipment — internal and inter-unit wiring in appliances and equipment that generate heat.
  • Telecommunications equipment — wiring in cabinets and enclosures where heat build-up is a design constraint.
  • Building services — high-temperature routes where a standard cable would degrade.

Lengths, Customization, and Certification

The standard coil is 95 m, and the length can be customized for a project. For other models in the range, lengths below 100 m are supplied as measured cut lengths. State the cross-section, the circuit current, and the route length, and the coil or cut length is set from those three inputs.

Certification is market-specific and is not fixed by the construction. Tell us the destination market — China, the EU, North America, or another region — and the certificate required for that market is confirmed before the order is placed, rather than assumed from the cable type.

To specify AGRP cable, four items are enough: the cross-section, the circuit voltage, the maximum temperature at the installation point, and the route length. Send them through the enquiry form on this page and the construction and the coil length are confirmed against them.

Sıkça Sorulan Sorular

Why does this cable use both silicone insulation and a fibreglass braid?

The two layers fail at different things. Silicone provides the dielectric strength and stays flexible across the temperature range, but it is soft and cuts through under abrasion. The fibreglass braid is the abrasion and radiant-heat barrier on the outside. A silicone cable without the braid would survive the temperature but not the mechanical duty; a braid without silicone would not insulate.

What happens to the cable in a fire?

The braid and the silicone resist the flame rather than feeding it, and the cable is self-extinguishing once the ignition source is removed. In a direct flame test the core remains intact after two minutes, which is the window needed to isolate the circuit. It is not a fire-rated circuit integrity cable for life-safety systems — for that duty a fire resistant cable to a fire test standard is the correct choice.

Can it be used outdoors or in wet locations?

The braided outer layer resists water and the construction survives prolonged immersion — the cable is intact after 60 days of immersion. That covers wash-down and wet process areas. For continuous outdoor UV exposure, confirm the application with us before ordering, because a braided outer layer is not the same as a UV-stabilised jacket.

What cross-sections are stocked, and can the length be customized?

The range covers 0.5, 1, 2.5, 4, and 6 mm². Standard coil length is 95 m, and the length can be customized for a project. State the cross-section, the circuit current, and the route length, and the coil or cut length is set from those.

Is this cable suitable as a replacement for a standard silicone cable?

Where the failure is abrasion or radiant heat rather than temperature alone, yes — the braid is the added layer. Where the existing cable is failing because of flexing in a moving application, a braided high-temperature cable is not the right substitution, and a drag chain or flexible cable should be selected instead.

Ürün Hakkında Sor

Ürün: AGRP High Temperature Cable 300°C — Fibreglass Braided Silicone Cable with Tinned Copper Conductor, Rated 300/500 V and −60 °C to +300 °C, for Metallurgy, Instrumentation, and Lighting

Teknik özellikleri ekleyin (isteğe bağlı)

Ne kadar çok ayrıntı verirseniz, teklifimiz o kadar hızlı ve doğru olur.

Dosya seçilmedi

PDF, Office, görsel veya CAD dosyası — en fazla 5 MB

Yardım mı Gerekiyor?

Sertifikalar

ISO 9001
Kalite
CE
Avrupa
RoHS
Çevresel
TÜV
Sertifikasyon

Bu Ürün İçin Teklif mi Gerekiyor?

Gereksinimlerinizi gönderin ve 24 saat içinde detaylı bir teklif alın.