UL1007 Hookup Wire — 300 V 80 °C PVC Insulated Single-Core Electronic Wire, 30 to 16 AWG Tinned Copper, UL 758 Listed Under File E531469, for Appliance and Equipment Internal Wiring
Силовые и высоковольтные кабели /UL AWM Hookup Wire

UL1007 Hookup Wire — 300 V 80 °C PVC Insulated Single-Core Electronic Wire, 30 to 16 AWG Tinned Copper, UL 758 Listed Under File E531469, for Appliance and Equipment Internal Wiring

UL1007 hookup wire: 300 V, 80 °C, PVC insulated single-core tinned copper wire from 30 to 16 AWG, UL 758 listed under file E531469, for appliance and equipment wiring.

Основные Характеристики

UL 758 listed under file E531469 — the AWM listing is what an inspector checks on an appliance or equipment build, and the file number is printed on the wire so it can be traced to the listing
300 V, 80 °C rating — the standard class for internal wiring in appliances and electronic equipment, where the conductor runs at low voltage and the enclosure temperature is the limiting factor
30 AWG to 16 AWG — the range covers a signal-level lead and a small power lead, so one wire type serves both inside the same enclosure
Tinned copper conductor — the tin coating stops the copper from oxidizing, which matters on a wire that is stripped and left in a terminal for years rather than potted
PVC insulation in a new compound — flame retardant and self-extinguishing once the flame is removed, with a smooth surface and no odour
Low eccentricity insulation wall — an even wall around the conductor is what prevents the thin spot that fails first when the wire is bent at a terminal
Fine stranding for a small bend radius — the wire is built to follow a tight route inside a chassis or a control box without springing back
Multiple colours available — red, black, brown, yellow, and green are standard, so a circuit can be colour-coded without sleeving

Применение

Appliance internal wiring — the leads between a terminal block, a switch, and a load inside a domestic applianceElectronic equipment internal wiring — signal and low-power leads inside a chassis, a control box, or an instrumentAutomotive internal connections — low-voltage internal wiring where a 300 V AWM wire is specifiedIndoor and outdoor lighting connections — the lead between a driver, a connector, and a lamp bodyControl panel wiring — short internal runs between terminals, relays, and indicatorsEquipment harness assembly — the individual leads inside a harness that is then bundled or sleeved

Технические Характеристики

Product Type UL1007 single-core hookup wire (AWM)
Standard UL 758 (Appliance Wiring Material)
UL File Number E531469
Rated Voltage 300 V
Temperature Range −30 °C to +80 °C
AWG Range 30 AWG to 16 AWG
Conductor Material Tinned copper, multi-strand
Conductor Construction (Examples) 11/0.16 TS, 17/0.16 TS, 21/0.178 TS, 34/0.178 TS, 26/0.254 TS (tinned strands)
Insulation PVC, new environmentally friendly compound
Insulation Property Flame retardant, self-extinguishing after removal of the ignition source, smooth surface, no odour
Eccentricity Low eccentricity, even insulation wall
Colours Red, black, brown, yellow, green; other colours available
Mechanical Properties Flexible, abrasion resistant, resistant to repeated bending, tensile resistant
Chemical Resistance Corrosion resistant
Marking Product designation, standard, temperature and voltage rating, and UL file number printed on the insulation
Certifications UL (file E531469), RoHS
Packing 100 m per coil; lengths below 100 m supplied as measured cut lengths
Application Appliance internal wiring, electronic equipment, automotive internal connections, lighting connections, control panels, harness assembly

Подробное Описание

Where UL1007 Fits Among Hookup Wires

UL1007 is the general-purpose single-core hookup wire of the UL AWM family: 300 V, 80 °C, PVC insulated, tinned copper, from 30 AWG to 16 AWG. It is the wire that runs between a terminal block and a switch inside an appliance, or between a connector and a board inside an instrument.

Its position in the family is defined by what it is not. UL1015 is the same idea at 600 V and 105 °C, with a thicker wall; UL1007 trades that headroom for a smaller diameter and more flexibility. For internal wiring in equipment that runs at mains voltage but a moderate enclosure temperature, UL1007 is the smaller and easier wire to route.

Construction: Tinned Copper and a 300 V PVC Wall

The build is deliberately simple, and each element is there for a specific reason:

  • Conductor — tinned copper, multi-strand. The stranding gives the wire a small bend radius, which is what allows it to follow a tight route inside a chassis; the tin coating is what keeps the conductor from oxidizing at a terminal that is stripped and left open for years.
  • Insulation — PVC in a new compound, extruded at a low-eccentricity wall. A 300 V rating is achieved with a relatively thin wall, so the evenness of that wall matters more than its thickness: the failure point on a bent wire is the thin side of an eccentric extrusion, not the nominal wall.
  • Marking — the insulation carries the product designation, the standard, the temperature and voltage rating, and the UL file number.

Ratings and the UL File

ParameterValue
StandardUL 758 (AWM)
UL file numberE531469
Rated voltage300 V
Temperature range−30 °C to +80 °C
AWG range30 to 16 AWG
ConductorTinned copper, multi-strand
InsulationPVC, flame retardant
ColoursRed, black, brown, yellow, green
Standard length100 m per coil
CertificationUL, RoHS

What the UL 758 Listing Means in Practice

The listing is the part that a buyer cannot verify from the datasheet, and it is the part that decides whether an appliance passes inspection.

UL 758 is the Appliance Wiring Material standard. The file number E531469 ties the wire to a specific listing that records the construction, the temperature and voltage rating, and the manufacturer. An inspector can take the number printed on the insulation and check it against the UL file — which is why the number is printed on the wire rather than only on the carton.

A wire without a traceable file number is not a listed AWM product, regardless of what the jacket print says. For a build that will be inspected, the file number is the item to record.

Where UL1007 Is Not the Right Wire

Three situations call for a different wire, and it is worth checking them before the build is fixed.

Where the circuit runs above 300 V, UL1007 is the wrong class — UL1015 carries 600 V at 105 °C with a thicker wall. Where the enclosure reaches above 80 °C in service, the 80 °C class is again the limiting item, and a 105 °C PVC or a silicone wire is the correct choice. Where the wire has to survive continuous flexing in a moving application, none of the hookup wire family is right, because these are fixed-installation wires; a drag chain cable is built for that duty.

For internal wiring in an appliance that runs at mains voltage and a moderate enclosure temperature, UL1007 remains the smaller and more flexible option.

Colours, Coils, and Ordering

Red, black, brown, yellow, and green are standard, and other colours are available on request. The colour range exists so that a circuit can be coded without adding sleeving, which matters in a tight enclosure where every millimetre of diameter counts.

Standard supply is a 100 m coil, with lengths below 100 m as measured cut lengths. Because the insulation carries the product designation and the ratings, a partly used coil remains identifiable.

To specify the wire, four items are enough: the AWG, the colour, the coil or cut length, and the insulation temperature the enclosure actually reaches. Send them through the enquiry form on this page, and the wire is matched to the build.

Часто задаваемые вопросы

What is the difference between UL1007 and UL1015?

The voltage and temperature class. UL1007 is 300 V and 80 °C; UL1015 is 600 V and 105 °C. UL1007 has a thinner insulation wall for the same AWG, so it is smaller and more flexible, and it is the usual choice for internal appliance and electronic wiring. UL1015 is chosen where the circuit runs at a higher voltage or the enclosure runs hotter.

What does the UL file number on the wire actually prove?

It ties the wire to a specific UL listing. An inspector can take the number printed on the jacket and check it against the UL file, which confirms the construction, the temperature and voltage rating, and the manufacturer. A wire without a traceable file number is not a listed AWM product, whatever the print on the jacket says.

Why is the conductor tinned rather than bare copper?

Oxidation. A bare copper conductor that is stripped and left in a terminal develops an oxide layer, and the oxide raises the contact resistance at exactly the point where the connection has to stay cool. Tinning protects the strands, so the joint stays stable over the service life of the appliance.

Can I get the wire in a colour that is not in the standard range?

Red, black, brown, yellow, and green are the standard colours. Other colours are available on request, which is useful where a circuit has to follow a specific colour code and sleeving is not wanted.

How is the wire supplied?

Standard supply is a 100 m coil, with lengths below 100 m as measured cut lengths. The insulation carries the product designation, the standard, the temperature and voltage rating, and the UL file number, so a partly used coil can still be identified.

Запрос по Товару

Продукт: UL1007 Hookup Wire — 300 V 80 °C PVC Insulated Single-Core Electronic Wire, 30 to 16 AWG Tinned Copper, UL 758 Listed Under File E531469, for Appliance and Equipment Internal Wiring

Добавить технические характеристики (необязательно)

Чем подробнее вы опишете задачу, тем быстрее и точнее мы подготовим предложение.

Файл не выбран

PDF, Office, изображение или CAD-файл — до 5 МБ

Нужна Помощь?

Сертификаты

ISO 9001
Качество
CE
Европейский
RoHS
Экологический
TÜV
Сертификация

Нужен Расчёт для Этого Продукта?

Отправьте нам ваши требования и получите подробный расчёт в течение 24 часов.